Canoga Perkins 2201 Rack Chassis/2200R Redundant Card
SW2-1 (SIMPLEX) This switch is only closed when the system is set up for
Simplex operation (data transmission in one direction
only). Only the switch at the transmit end is closed.
SW2-2 (EXTCLK) This switch determines whether both directions of data
flow will be switched together or not. When SW2-2 is
OPEN, both directions of data flow switch together
(operations on both primary modems or both secondary
modems). With the switch closed, the primary modems
can be sending data in one direction while the second-
ary modems are sending data in the other direction. If
the modems are configured for INTERNAL CLOCK,
SW2-2 must be open. Either position of this switch may
be used for EXTERNAL CLOCK operation with the
resulting switching differences described above. For the
sake of simplicity, it is recommended that this switch be
left in the OPEN position.
SW2-3 (SYNC) This switch must be set to the OPEN position for all
modem types except the 2240. For use with 2240s,
SW2-3 must be CLOSED.
SW2-4 (SP-1) This is a spare switch.
NOTE: For Models 2270 and 2290, if the internal clock mode is
configured, the flow control option on the modems must be en
abled. The flow control operation of the modem is required for
proper redundant switching.
Two jumpers are provided, W7 and W8, for configuring chassis ground connections.
Jumper W7 connects signal ground to chassis ground. Jumper W8 allows the signal
ground to float. Note that the W2 jumper on the power distribution board can override
the W7/W8 jumper. Refer to Section 2.1.2 for more information.