23
2201 Rack Chassis/2200R Redundant Card Canoga Perkins
Step Symptom Possible Cause(s) Action
6 Replace any bad fuses with good fuses of the proper rating. With the
power on, insert the cards into the chassis, one at a time. Replace any
cards that cause the power supply to fail. Replace power supply fuses as
necessary. Proceed to Step 7.
7 Check the secondary power supply voltages as described in Section 3.2 of
the manual. If anyvoltage is bad, replace the power supply.
8 Same as Step 4, but Bad modem Return modem for
output voltage is repair.
normal.
9 Failure indicator lit Low input voltage Check main power
on 2201 power monitor source.
card. All front panel
power indicators lit.
All units functioning.
10 " " " Output low voltage Perform Step 6.
caused by bad modem.
11 " " " 2201 monitor card
switch set wrong
12 " " " Bad monitor card Replace supply
monitor card.
Page view 22