22
Canoga Perkins 2201 Rack Chassis/2200R Redundant Card
4. Diagnostic Procedures
The following diagnostic procedures assume that at least one modem is installed in
the 2201 to be able to troubleshoot and isolate a defective modem, power supply or
monitor card.
Required Equipment
Multimeter - (for voltage, resistance and continuity tests)
Step Symptom Possible Cause(s) Action
1 No power indicator No Main power Check Main power
on front panel(s). source.
Power indicator
out on R/M supply.
2 Same as Step 1 Blown Main fuse Remove power and
check Main fuse at
rear of power
supply.
3 No power indicator Blown secondary Check secondary
on front panel(s). fuses fuses. See section
Power indicator 3.3.
lit on R/M supply.
Failure indicator
lit on 2201 Power
Monitor Board.
4 Same as Step 3, but Low voltage output Go to Step 7.
fuses are good.
5 If any fuse is bad, replace it with a good fuse of the proper rating. If the
power supply still blows the fuse, unplug all the cards from the chassis,
replace the defective fuse, and turn on the power. If the fuse still blows,
replace the chassis.