3-30 9145 Network Interface Device
4. At the prompt, select the Source, which is the inactive bank for the local module, then
select the Destination, which is the inactive bank for the remote module, and press
<Enter>; the upgrade runs automatically.
To run the new software, swap banks, and reset the module. Follow these steps:
1. From the Main Menu, type [
7], "Software Upgrade," and press <Enter>.
2. At the Software Upgrade Menu, type [
2], "Swap Bank & Reset," press <Tab> to highlight
the Remote column, and press <Enter>.
3. Type [
2], "Swap Bank & Reset," check that the Local column is highlighted, and press
<Enter>. Both modules reset and start using the new firmware.
Configuring Access Security
The 9145 has comprehensive management access security features, including SNMPv3
authorization, RADIUS, configurable password formatting and user access controls. Typically,
you must have supervisor access to configure and manage security for the 9145.
Canoga Perkins Corp. Ethernet Network Inter
f
ace Device 04-Dec-2006
Model 9145-5 V96.05 F96 9145 DC_172.16.142.225 07:38:04
------------------------------------SOFTWARE UPGRADE----------------------------
Time Since Last Restart 2 days 13:53:23
Local Remote Offline
Last Data
Active Firmware 96.05
Inactive Firmware 12.15
Bootcode 06.30
1) Software Reset Reset Reset
2) Swap Bank & Reset Swap Swap
3) Get New File with TFTP
Select [1-3]:
------------------------------------Messages------------------------------------
Swap
Page view 47