3-48 9145 Network Interface Device
Priority (0 - 7)
Sets P-Bit of VLAN Tag B. Values of 0-7 are Valid.
9. Tag C VLAN ID (0-4095)
Sets VLAN ID for Tag C. ID setting of 0 – 4095 are valid.
Priority (0 - 7)
Internet Explorer.lnk
Sets P-Bit of VLAN Tag C. Values of 0-7 are Valid.
4. To return to the Main Menu, press <Esc>.
The 9145 can change VLAN Tag IDs on user packets. This is useful to avoid VLAN ID conflicts
in the network. The 9145 can translate up to 8 VLAN IDs. To Configure VLAN Translations so
outgoing packets receive a new tag based on the previous tag, follow these steps:
1. From the Main Menu type [
3], "Port Information," and press <Enter>. At the Port Information
Menu, type [
2], "Port Configuration," and press <Enter>. At the Port Configuration Menu,
type [
3], "VLAN Configuration, and press <Enter>.
2. At the VLAN Configuration Menu, type [
2], "VLAN ID Translation Table," and press
<Enter>."
3. To add an entry to the Table or change an existing entry, type the entry number (1 to 8). As
you enter VLAN IDs, the cursor will automatically move from one column to the next. If the
9145 will corrected to a remote 9145 and SBMC is enabled, the remote 9145 will also be
configured.
Type the VLAN ID the 9145 will receive from the Local User Port - In VLAN and press
<Enter>.
Type the VLAN ID the 9145 will change the In VLAN ID into and send on the Extension
Port (Local User Port - Out VLAN) press <Enter>.
Type the VLAN ID the 9145 will receive from the Local Ext Port - In VLAN and press
<Enter>.
Type the VLAN ID the 9145 will change the In VLAN ID into and send on the Extension
Canoga Perkins Corp. Ethernet Network Inter
f
ace Device 04-Dec-2006
Model 9145-5 V96.05 F96 9145 DC_172.16.142.225 07:01:53
-----------------------------VLAN ID TRANSLATION TABLE--------------------------
Local User Port Local Ext Port Remote
In VLAN Out VLAN Out VLAN In VLAN Offline
------- -------- -------- -------
1) 0 0 0 0
2) 0 0 0 0
3) 0 0 0 0
4) 0 0 0 0
5) 0 0 0 0
6) 0 0 0 0
7) 0 0 0 0
8) 0 0 0 0
9) Enable VLAN
Translation? No No
Select [1-9]: